3/20/2024 0 Comments Blue iris tools 64 bit download![]() ![]() Once releasing the Force option toggle then trigger the same DIO to "unlatch" the relevant DIO output.Download Blue Iris 5 - Professional surveillance software allows you to view and record up to 64 IP cameras, web cameras, cameras Blue Iris:īlue Iris is professional surveillance software that allows you to view and record up to 64 cameras (IP cameras, web cameras, DVR / CCTV based cameras) simultaneously and is compatible with the vast majority of IP camera brands. Blue Iris Force option sends the on Bytes S01, S11, S21 and S31 but does not send the corresponding off bytes namely S00, S10, S20 and S30 when the force toggle is released ![]() With GCE Electronics selected as a protocol for serial port in Blue Iris Digital I/O settings sends three bytes for DIO Outputs controls as follows: Static int OptionalControlPin13 = 13 //OptionalControlPin13, assigns pin: ![]() If you use pin 13 for something else remove its OptionalControlPin13 configurations below: which may pre-maturely or unintentionally activate and relays connected to pin 13 in a power-fail or initial connection to PC situation: ![]() The onboard SMD LED on pin 13 is used by the optiboot loader on Arduino UNO and it is recommended not to be used as pre-mature or unintended cycle hi/lo during boot (the LED blinks a few times) Alert bit bytes:action n bytes:action ff Below table of Blue Iris digital output bits, their corresponding serial data sent to Arduino and the resulting anticipated actions when triggered: Assign Arduino pin's that correspond to Blue Iris DIO Output functions and Set digital output bits for Camera alerts: Ken from Blue Iris will be placing this on his website in the near future but asked that I place it on the forum in the interim. I have written my serial.read Arduino code to look at three bytes " >2", but if you want to do some other funky stuff I suggest you run a serial port monitor, observe the serial outputs from Blue Iris and then write your code to suit. The DIO output triggers in the app generate S01,S11,S21,S31 for ON and correspondingly a S00,S10,S20, S30 for OFF. In version 4.0.9.x, the outputs for DIO Trigger Output and Alerts trigger output changed, the full map is in my posted code below.Įssentially Alert bit's 16, 32, 64, 128 produce an corresponding ASCII output to serial of S41,S51,S61,S71 for ON and correspondingly S40,S50,S60, S70 for OFF. I have kept my code simple for illustration and you can find it further below. So your serial read "if" loop should read in the first three bytes, then process. (I have to write yet sketch that exclude multiply series of DIO sent by BI) Sent by BI for 15 sec continuos when camera alert is fired. In the opposite direction, BI to arduino, with serial.read() i receive correctly number 48,49,50. Just serial.write(8) trig the just ONE camera with DIO 8 selected in the trig/motion option 64ĪLWAYS MANY CAMERA (with different DIO) ARE SIMULTANEUS TIGGERED with a ONLY digit sent !!!!!įor example SERIAL.WRITE(4) activate camera with DIO 1,3,4,5,6.!!! "serial.write(n)" or serial.print() or serial.println() or serial.print(n, BIT) or When I send on the serial port DIO number with ARDUINO by using Now I bought BI 64-bit with Win7 and i have connectedīI with my Arduino Alarm system PIR controlīut i loosed a lot of time and I HAVE THE SAME PROBLEM and I really tried everything!!! I tried to connect BI & Arduino before with XP ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |